Starten Sie Ihre Suche...


Durch die Nutzung unserer Webseite erklären Sie sich damit einverstanden, dass wir Cookies verwenden. Weitere Informationen

A prospective randomized multicenter study to evaluate the performance of the CAMLOG® SCREW-LINE Implants used with standard abutments or with abutments for platform switching

Laufzeit: 01.01.2009 - 31.12.2015

Kurzfassung


The study is a prospective randomized multicenter study to evaluate the performance of
CAMLOG SCREW-LINE implant supporting single crowns in the posterior mandible
restored either with standard abutments or with abutment for platform switching (Positions
37-34 and/or 44-47). Implants will be randomized in two groups
Group A Implants in the posterior mandible restored with PS abutments for platform
switching
Group B Implants in the posterior mandible restored with standard abutments
The primary...
The study is a prospective randomized multicenter study to evaluate the performance of
CAMLOG® SCREW-LINE implant supporting single crowns in the posterior mandible
restored either with standard abutments or with abutment for platform switching (Positions
37-34 and/or 44-47). Implants will be randomized in two groups
Group A Implants in the posterior mandible restored with PS abutments for platform
switching
Group B Implants in the posterior mandible restored with standard abutments
The primary objective is the statistical evaluation of significant changes in crestal bone levels
between the two abutment types overtime.
Secondary objectives include implant success and survival at 1, 2, 3, 4, and 5 years post
loading, performance of the restorative components, nature and frequency of the adverse
events.
» weiterlesen» einklappen

Beteiligte Einrichtungen